X
Category:
Dayton Audio OmniMic V2 Acoustic Measurement System
Dayton Audio OmniMic V2 Acoustic Measurement System
Dayton Audio OmniMic V2 Acoustic Measurement System
Dayton Audio OmniMic V2 Acoustic Measurement System
Dayton Audio OmniMic V2 Acoustic Measurement System
Dayton Audio OmniMic V2 Acoustic Measurement System
Dayton Audio OmniMic V2 Acoustic Measurement System
Dayton Audio OmniMic V2 Acoustic Measurement System
Dayton Audio OmniMic V2 Acoustic Measurement System
Dayton Audio OmniMic V2 Acoustic Measurement System

Dayton Audio OmniMic V2 Acoustic Measurement System

Product ID : 1572348
4.3 out of 5 stars


Galleon Product ID 1572348
UPC / ISBN 844632098277
Shipping Weight 1.94 lbs
I think this is wrong?
Model 390-792
Manufacturer Dayton Audio
Shipping Dimension 10.24 x 8.74 x 2.99 inches
I think this is wrong?
-
Product is Out of Stock as of Jan, 27 2024
Want to monitor availability?
of brand new stock?
or
Need this item ASAP?
Check if this is available on Amazon
or available in other sites
Send us the link so we can buy for you

Pay with

Dayton Audio OmniMic V2 Acoustic Measurement System Features

  • Updated software and improved hardware

  • Compact, portable, accurate, affordable

  • Intuitive software--open the box, start testing in minutes

  • Perfect for setting up home theater systems

  • Optimized for use with netbooks and laptops


About Dayton Audio OmniMic V2 Acoustic Measurement System

Quick Overview Dayton Audios OmniMic V2 is a must-have omnidirectional acoustic measurement system for audio system integrators, acoustic engineers, and residential A/V installers. The OmniMic V2s new hardware provides fast, comprehensive, and accurate audio measurements. Product Highlights Updated software and improved hardware Compact, portable, accurate, affordable Intuitive software—open the box, start testing in minutes Perfect for setting up home theater systems Optimized for use with netbooks and laptops Accurate response down to 5 Hz, fully calibrated, includes FRD file For professionals and hobbyists—design and tune speaker systems and arrays Product Manuals / Spec Sheets / Downloads OmniMic V2 Quick Reference Guide OmniMic V2 User Manual AddThis Sharing Buttons Share to FacebookFacebook Share to TwitterTwitter Share to MoreAddThis 8 Product Description OmniMic V2 Calibration File Look Up Have your OmniMic V2 custom calibrated instantly Enter the NUMERIC serial number found on the base of your calibrated OmniMic. After entering the serial number, your unique calibration .omm file will be available for you to download. International Users: Please note that the language setting in your Windows operating system must be set to “English” to open a *.omm calibration file for your OmniMic hardware within the OmniMic software. We are working to correct this known issue in a future software release. Download Measurement Microphone Calibration Files PLEASE NOTE: If you own an original OmniMic you qualify for a free calibration. Follow the instructions below to have your microphone calibrated. Send your OmniMic to: Dayton Audio Attn: Calibration Department, 705 Pleasant Valley Drive, Springboro, Ohio 45066 Upon receipt of your original OmniMic, you will be informed via email when it has been calibrated and on its way back to you. Please include your name, shipping address, daytime phone number, and email address with your OmniMic. Please allow 7-10 days for calibration and return shipping. Calibration and return shipping are at no charge. Latest software version The latest software version is: VERSION 5.2 Click Here To Download OmniMic 5.2 Whats New: • Improved impulse response peak finding • Much improved blend impulse response windowing, non-abrupt and now emphasizes activity earlier in the IR according to frequency and time position • IEC263 Standard graph format option for Frequency Response, for use in professional published reports • No longer requires WinXP emulation mode for proper SPL readings • Function to apply smoothing to all active Added Curves in one click • Now supports up to 40 Added Curves in Frequency Response for detailed polar data measurements • New keystroke actions: The [Space bar] Pauses and unPauses analyzer capture from the microphone. The [Enter] key brings up the menu for curve saves and Auto-polar-angle increment saves on Frequency Response tab. When capturing a series of Frequency Response measurements over a range of angles, just press [Enter] three times. • Loudspeaker SPL capability estimate features: IP2 (second order distortion intercept) and IP3 (third order distortion intercept) curve options in the Distortion Analyzer • Option for thicker distortion product curve traces in the Distortion Analyzer • Improved snaptshot filesave and print quality with better readability of characters • Perceptual ERB (Equivalent Rectangular Bandwidth) Smoothing option for Frequency Response curves to simulate sensitivity of human hearing to response smoothness • The shape of the Impuse Response window is now drawn on the Impulse Response graph in linear mode • Certain graphs settings and Frequency Response options are saved on closing Omnimic and restored on the next run • "Tail correction" tools provided for most accurately calculating minimum phase curves • Slightly more modernized graphics • Impulse Response synch fixed with MLS • Synch in Harmonic Distortion measurement fixed • Selection of white or color