X
Category:
Hioki 3490 Analog Megohm HiTester, 4000 Megohms
Hioki 3490 Analog Megohm HiTester, 4000 Megohms
Hioki 3490 Analog Megohm HiTester, 4000 Megohms
Hioki 3490 Analog Megohm HiTester, 4000 Megohms

Hioki 3490 Analog Megohm HiTester, 4000 Megohms Resistance, 250V, 500V, 1000V DC Test Voltage

Product ID : 14041746
5 out of 5 stars


Galleon Product ID 14041746
Shipping Weight 1.85 lbs
I think this is wrong?
Model 3490
Manufacturer Hioki
Shipping Dimension 8.5 x 6.5 x 2.28 inches
I think this is wrong?
-
40,805

*Price and Stocks may change without prior notice
*Packaging of actual item may differ from photo shown

Pay with

Hioki 3490 Analog Megohm HiTester, 4000 Megohms Features

  • Insulation testing in 3 easy steps, flip the cover, select range and test

  • 3-Range testing voltage 250/500 v (insulation meter up to 100 m ohm), and 1000 v (insulation meter up to 4000 m ohm)

  • Continuity check, 3 ohm range via 200 mA testing

  • Bright LED luminous scale

  • Check for live circuits and for the battery status


About Hioki 3490 Analog Megohm HiTester, 4000 Megohms

Insulation testing in 3 easy steps, flip the cover, select range and test. 3-Range testing voltage 250/500 v (insulation meter up to 100 m ohm), and 1000 v (insulation meter up to 4000 m ohm). Continuity check, 3 ohm range via 200 mA testing. Bright LED luminous scale. Check for live circuits and for the battery status. Accuracy guaranteed for 1 year. Testing voltage: 250 V DC, 500 V DC, 1000 V DC. Rated resistance: 250 V DC: 100 M ohm, 500 V DC: 100 M ohm, 1000 V DC: 4000 M ohm. Accuracy 1st effective measuring range: 250 V DC: +/-5 percent of indicated value 0.05 to 50 M ohm, 500 V DC: +/-5 percent of indicated value 0.05 to 50 M ohm, 1000 V DC: +/-5 percent of indicated value 2 to 1000 M ohm. Lower limit resistance: 250 V DC: 0.25 M ohm, 500 V DC: 0.5 M ohm, 1000 V DC: 1 M ohm, (measurement resistance value to maintain testing voltage). Overload protection: 1200 V AC (10 sec.). Low resistance: 3 ohm (at 200 mA testing current), +/-0.09 ohm accuracy, 30 ohm (at 20 mA testing current), +/-0.9 ohm accuracy, Open-circuit voltage: 4.1 to 6.9 V. AC voltage measurement: 0 to 600 V (50/60 Hz), +/-5 percent of maximum scale value accuracy, 100 k ohm or more input resistance. Other functions: Bright led luminous scale, drop proof (on concrete, 1 m/1 time), battery check, live circuit check, auto discharge. Power supply: LR6 (AA) alkaline batteries ×4, continuous use: 20 hours (at 500 V range, no load). Supplied accessories: test lead L9787 ×1, instruction manual ×1, LR6 (AA) alkaline batteries ×4, shoulder strap ×1. Measures 6-1/4" width by 6-31/32" height by 2-5/64" depth.