The regulation is performed according to the temperature measured by the thermostat probe with a positive differential from the set point: if the temperature increases and reaches set point plus differential the compressor is started and then turned off when the temperature reaches the set point value again.In case of fault in the thermostat probe the start and stop of the compressor are timed through parameters COn and COF.
Two defrost modes are available through the tdF parameter:defrost through electrical heater (tdF= EL) and hot gas defrost (tdF = in).Other parameters are used to control the interval between defrost cycles (IdF), its maximum length (MdF) and two defrost modes: timed or controlled by the evaporator?s probe (P2P).At the end of defrost dripping time is started, its length is set in the FSt parameter. With FSt =0 the dripping time is disabled.
Forced activation of fans This function managed by the Fct parameter is designed to avoid short cycles of fans, that could happen when the controller is switched on or after a defrost, when the room air warms the evaporator. Functioning: if the difference of temperature between the evaporator and the room probes is more than the value of the Fct parameter, the fans are switched on. With Fct=0 the function is disabled.
Cyclical activation of the fans with compressor off. When Fnc = c-n or c-Y (fans in parallel to the compressor), by means of the Fon and FoF parameters the fans can carry out on and off cycles even if the compressor is switched off. When the compressor is stopped the fans go on working for the Fon time. With Fon =0 the fans remain always off, when the compressor is off.
Suitable for applications on medium or low temperature ventilated refrigerating units.XR60CX-5N1C1,230V/50-60Hz
Model XR60CX,format 32 x 74 mm,is microprocessor based controller,suitable for applications on medium or low temperature ventilated refrigerating units.It has three relay outputs to control compressor, fan, and defrost,which can be either electrical or reverse cycle (hot gas).It is also provided with three NTC or PTC probe inputs,the first one for temperature control, the second one,to be located onto the evaporator,to control the defrost termination temperature and to managed the fan, the third one,optional,to connect to the HOT KEY terminals to signal the condenser temperature alarm or to display a temperature.The digital input can operate as fourth temperature probe. The HOT KEY output allows to connect the unit,by means of the external module XJ485-CX, to a network line ModBUS-RTU compatible such as the Dixell monitoring units of X-WEB family.It allows to program the controller by means the HOT KEY programming keyboard.The instrument is fully configurable through special parameters that can be easily programmed through the keyboard. Specification Housing: self extinguishing ABS. Case: XR60CX frontal 32x74 mm,depth 60mm; Mounting: XR60CX panel mounting in a 71x29mm panel cut-out Protection: IP20. Connections:Screw terminal block ± 2,5 mm2 wiring. Power supply:according to the model:230Vac ±10% 50/60Hz Power absorption:3VA max Display:3 digits,red LED,14,2 mm high; Inputs: Up to 4 NTC or PTC probes. Digital input:free voltage contact Relay outputs:compressor SPST 8(3) A,250Vac;or 20(8)A 250Vac Data storing: on the non-volatile memory (EEPROM). Kind of action: 1B; Pollution grade: 2;Software class: A. Package Include 1 X Dixell XR60CX Digital Thermostat Controller