All Categories
♥♥【Application】:The dental pulp tester is an instrument that uses a machine to produce pulse current and stimulates the tooth nerve, then records the response value of the tooth nerve to the electrical stimulation, so as to judge the status of the tooth nerve,which ensure the accuracy of doctor's judgement on the patient's pulp status
♥♥【Adjustable Frequency】:To press the speed control button to choose three preset speed mode (high-mid-low speed),while the different indicator lights will be on.
♥♥【Data description】:The maximum stimulus----80.Between 0-40, the patient feels ache and anesthesia, it is the alive teeth nerve.Between 40-80,with above-mentioned reaction,part of teeth nerve dead. 80, no above-mentioned reaction, dead teeth nerve.
♥♥【About Testing】:To increase a gentle pulsed stimulus at a rate,If the patient indicates perception, simply release the button. The stimulus stops immediately, but the numbers remain on the tester for about 3 minutes.It is easy to read.
♥♥【Economical】:This pulp tester is battery-operated, Standard 9-Volt batteries, the device turns itself off three minutes later after operation(No wasted batteries.)
♥Pulp Tester,Fencia Dental Pulp Tester Teeth Nerve Detector Endodontic Measuring Tools ♥♥【Application】:The dental pulp tester is an instrument that uses a machine to produce pulse current and stimulates the tooth nerve, then records the response value of the tooth nerve to the electrical stimulation, so as to judge the status of the tooth nerve,which ensure the accuracy of the user's judgement on the patient's pulp ♥♥【Adjustable Frequency】:To press the speed control button to choose three preset speed mode(high-mid-low speed),while the different indicator lights will be on. ♥♥【Data description】:The maximum stimulus----80.Between 0-40, the patient feels ache and anesthesia, it is the alive teeth nerve.Between 40-80,with above-mentioned reaction,part of teeth nerve dead. 80, no above-mentioned reaction, dead teeth nerve. ♥♥【About Testing】:To increase a gentle pulsed stimulus at a rate,If the patient indicates perception, simply release the button. The stimulus stops immediately, but the numbers remain on the tester for about 3 minutes.It is easy to read. ♥✉If you have any question about the products, please feel free to contact us,we will deal with the issue immediately and carefully until you are satisfied. ◆Specifications : Input:Maximun 80V output:DC 9.0V Current:90mA Voltage Range:DC 6.0-10.0V Size:186*38*24mm Net Weight:220g ●Package List: Pulp tester*1 Test electrodex*2 Test wire*1 User manual x1pcs Stainless hookx4pcs