Kyoritsu 2002PA Digital Clamp-Meter, 2000A
Kyoritsu 2002PA Digital Clamp-Meter, 2000A

Kyoritsu 2002PA Digital Clamp-Meter, 2000A AC, Conductors to 55mm, Voltage and Resistance Measurement

Product ID : 1571244


Galleon Product ID 1571244
Shipping Weight 1.85 lbs
I think this is wrong?
Model 2002PA
Manufacturer Kyoritsu
Shipping Dimension 10.39 x 5.51 x 2.28 inches
I think this is wrong?
-
No price yet.
Price not yet available.

Pay with

Kyoritsu 2002PA Digital Clamp-Meter, 2000A Features

  • Digital clamp-meter measures AC to 2,000A, AC voltage to 750V, DC voltage to 1,000V, and resistance to 4,000 kilohms

  • Average-sensing meter provides accurate readings when measuring linear loads, where the current or voltage has a sinusoidal waveform

  • Clamp with 55mm (2.16 inches) jaw opening measures current without touching or interrupting the circuit

  • Peak hold function captures the highest reading of inrush current at the startup of motors and other inductive loads

  • Meets IEC safety standards 61010-1, 61010-031, and 61010-2-032, and is rated for CAT III installations to 600V and CAT II installations to 1,000V


About Kyoritsu 2002PA Digital Clamp-Meter, 2000A

The Kyoritsu 2002PA digital clamp-meter is an average-sensing, manual- and auto-ranging multimeter for measuring current, voltage, and resistance in electrical testing applications. It has a clamp that measures AC (alternating current) to 2,000A (amperes). The clamp has two jaws that can close around an electrical conductor up to 55mm (2.16 inches) in diameter to measure current without touching or interrupting the circuit. A set of test leads is included for measuring AC voltage to 750V, DC voltage to 1,000V, and resistance to 4,000kΩ (kilohms). The meter has a rotary switch to select the property to measure, and a 4,000-count LCD. The peak hold function, using a 10ms (millisecond) sampling time, captures the highest reading of the inrush current at the startup of motors and other inductive loads. To aid documentation of readings and capture readings in tight spaces, the data hold function keeps the most recent reading on the display after disconnecting from the circuit. A continuity buzzer confirms that the circuit conducts electricity. For long-term monitoring of current, the meter comes with an output plug for attaching to a recording device (sold separately). The unit operates on two 1.5V AA batteries, and turns off automatically after 10 minutes of non-use to conserve battery life. It has a low-battery indicator that signals when the battery needs to be replaced. This average-sensing, also called average responding or mean value, meter provides accurate readings when measuring linear loads, such as standard induction motors and incandescent lights, where the current or voltage has a sinusoidal waveform. It is manual-ranging for current to allow operator control of measurements, and auto-ranging for voltage and resistance, so it automatically selects the appropriate operating range. Accuracy and resolution specifications vary according to the range being measured. The meter meets IEC (International Electrotechnical Commission) safety standards 61010-1, 61010-031, and 61010-2-032, and is rated for CAT (category) III installations to 600V, which covers equipment in fixed installations, such as switches in the fixed installation and some industrial equipment that is permanently connected to the fixed installation, and CAT II installations up to 1,000V for voltage measurement, which covers energy-consuming equipment connected to a fixed installation, including household, office, and laboratory appliances. It has CE (European Conformity) marking. The unit comes with a carrying case. Specifications Maximum AC (alternating current) input2,000AMaximum AC voltage input750VMaximum DC (direct current) voltage input1,000VMaximum resistance detected4,000kΩInstallation ratingCAT III, 600V; CAT II, 1,000V Standards metIEC safety standards 61010-1, 61010-031, and 61010-2-032; CE markingPower supply 1.5V AA batteries (two, installed)Weight470g/16.6oz.Dimensions (H x W x D)247 x 105 x 49mm/9.72 x 4.13 x 1.93 inches H is height, the vertical distance from lowest to highest point; W is width, the horizontal distance from left to right; D is depth, the horizontal distance from front to back. Clamp-meters, also called clamp-on meters, have two jaws that fit around a conductor to measure electrical current without cutting through wires, or touching or interrupting the electrical circuit. Available in handheld or benchtop models, clamp-meters diagnose problems in electrical equipment, wiring, and power supplies. All clamp-meters test for current. Some come with test leads and inputs for measuring voltage, capacitance, and resistance. They display information either in analog or digital form. Factors that influence meter choice include the electrical properties to be measured, the anticipated range of results, and the desired level of protection against transient voltage. Safety ratings are based on International Electrotechnical Commission (IEC) standards for low-voltage test equipment. IEC 61010 delineates four overvoltage installation categor