X
Fluke 705 Loop Calibrator, 28V Voltage, 24mA
Fluke 705 Loop Calibrator, 28V Voltage, 24mA
Fluke 705 Loop Calibrator, 28V Voltage, 24mA

Fluke 705 Loop Calibrator, 28V Voltage, 24mA Current, 0.025 percent Accuracy

Product ID : 9174527
4.8 out of 5 stars


Galleon Product ID 9174527
UPC / ISBN 095969062565
Shipping Weight 1.61 lbs
I think this is wrong?
Model FLUKE-705
Manufacturer Fluke
Shipping Dimension 10.16 x 6.06 x 3.27 inches
I think this is wrong?
-
Save 18%
Before ₱ 110,989
91,448

*Price and Stocks may change without prior notice
*Packaging of actual item may differ from photo shown

Pay with

Fluke 705 Loop Calibrator, 28V Voltage, 24mA Features

  • For a powerful loop calibrator at a very affordable price, choose the new Fluke 705 Loop Calibrator. This feature-rich solution to loop calibration, maintenance and repair offers: A large display and simple, pushbutton interface for ease of use

  • Simultaneous mA and % readout for quick, easy interpretation of readings

  • mA accuracy of 0.02%

  • Push button 25% steps for fast, easy linearity checks. Save time over traditional knob type controls

  • "Span Check" for fast confirmation of zero and span


About Fluke 705 Loop Calibrator, 28V Voltage, 24mA

Loop Calibrator is a cost-effective, integrated solution for calibration, repair and maintenance of current loops. A large display and simple, pushbutton interface for ease of use. Simultaneous mA and percent readout for quick, easy interpretation of readings. mA accuracy of 0.02 percent. Push button 25 percent steps for fast, easy linearity checks. Save time over traditional knob type controls. "Span Check" for fast confirmation of zero and span. Selectable slow ramp, fast ramp, and step to provide smooth outputs for valve slewing and loop functional tests. 24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM. Single 9V battery that is easily changed. 0 - 20 mA or 4 - 20 mA default start up modes. 0.02 percent accuracy and 0.001 mA resolution. Simultaneous mA and percent of span display. Selectable step or ramp outputs. 24V Loop supply with mA measure. 0-28 VDC measurement to check Loop Voltage. Easy battery exchange without opening the case. Compact case with separate protective holster. 3 year warranty. Current measurement: : 0 to 24 mA range, 0.001 mA resolution, 0.02 percent Rdg + 2 LSD accuracy. Voltage measurement: : 0 to 28V DC range, 1 mV resolution, 0.025 percent Rdg + 2 LSD accuracy. Loop power: while measuring mA, 24V. Operating temperature: -10/55 degree C. Storage temperature: -40/60 degree C. Measures 152mm length by 70mm width by 41mm depth. Loop calibrator including: AC70A alligator clips, C10 protective yellow holster with Flex-Stand, instruction sheet, TL75 safety-designed test lead set, NIST- traceable calibration report and data. Weight: 340g.