X
NOYITO ACS758LCB-050B-PFF-T Linear Current Sensor
NOYITO ACS758LCB-050B-PFF-T Linear Current Sensor
NOYITO ACS758LCB-050B-PFF-T Linear Current Sensor
NOYITO ACS758LCB-050B-PFF-T Linear Current Sensor
NOYITO ACS758LCB-050B-PFF-T Linear Current Sensor
NOYITO ACS758LCB-050B-PFF-T Linear Current Sensor

NOYITO ACS758LCB-050B-PFF-T Linear Current Sensor Hall Current Module

Product ID : 41699943


Galleon Product ID 41699943
UPC / ISBN 680613662057
Shipping Weight 0.02 lbs
I think this is wrong?
Model ACS758LCB-050B-PFF-T
Manufacturer NOYITO
Shipping Dimension 4.96 x 3.27 x 0.28 inches
I think this is wrong?
-
Save 29%
Before ₱ 1,235
876

*Price and Stocks may change without prior notice
*Packaging of actual item may differ from photo shown
  • Electrical items MAY be 110 volts.
  • 7 Day Return Policy
  • All products are genuine and original
  • Cash On Delivery/Cash Upon Pickup Available

Pay with

NOYITO ACS758LCB-050B-PFF-T Linear Current Sensor Features

  • This product is a current detection module, mainly using the ACS758-LCB current sensor. The ACS758 consists of a precision, low-offset linear Hall sensor circuit with a copper current path close to the wafer. The current applied through the copper current path is capable of generating a magnetic field that can be induced by the integrated Hall IC and converted to a proportional voltage.

  • Device accuracy is optimized by placing the magnetic signal close to the Hall sensor. The accurate, proportional output voltage is provided by a stable chopper-type, low-bias BiCMOS Hall IC that is factory-precisely programmed.

  • The internal resistance of this conduction path is typically 100 μΩ with low power loss. The thickness of the copper wire allows the device to operate under high overcurrent conditions. The terminals of the conduction path are electrically isolated from the sensor pins (pins 1 to 3). In this way, the ACS758 sensor IC family can be used in applications that require electrical insulation without the use of opto-insulators or other expensive insulation techniques.

  • Perform RC filtering on the output and use the op amp to build a voltage follower circuit to make the output more stable and better match the impedance of the A/D channel of the microcontroller. At the same time, two output pins are taken out (direct output and voltage follower output) for easy selection.

  • Detection current range ±50 A.

  • 【This product has a two-year after-sales warranty, we expect the real order and use of the user to provide the use of feedback, which will be an important basis for us to upgrade the product.】


About NOYITO ACS758LCB-050B-PFF-T Linear Current Sensor

Parameter Working voltage: 3V - 5 V (MAX 8 V) Static output voltage: VCC/2 Working current: 13.5 mA (MAX) Storage temperature range: -65 °C – 165 °C The maximum output current (VIOUT-GND): 3 mA Internal bandwidth: 120 KHz Module size: 37mm X 18mm Module weight: 8.8 g Features: Industry-leading noise performance through patented amplifier and filter design processes Integrated shielding significantly reduces current conductor-to-wafer capacitive coupling due to high dV/dt signals and prevents bias drift in high-end, high-voltage applications. Improve total output error rate by temperature gain and offset adjustment Small package size for easy installation High reliability monolithic Hall IC Ultra low power loss: internal conduction resistance 100 μΩ Insulation design enables economical high-end current sensing in high voltage systems Meets AEC Q-100 standards 3.0 to 5.5V, single supply operation 120 kHz typical bandwidth Corresponding to the step input current, the output rise time is 3 μs Output voltage is proportional to AC or DC current Calibrated at the factory to ensure accuracy Extremely stable output offset voltage Near zero hysteresis The relationship between voltage output and current input: VOUT = VOUT(Q) + Vsens x I VOUT(Q) is the static output voltage, which is VCC/2, which is the output voltage when there is no input. Vsens is a sensor-sensitive scale, also known as a coefficient. I is the current flowing from IP+ to IP-. For example, suppose the sensor model is 050B, VCC is 5V, and“I” current is 10A, then the output is 5V / 2 + 40mV / A x 10A = 2.9V. Package Included: 1pcs NOYITO ACS758LCB-050B-PFF-T Linear Current Sensor Hall Current Module