X
Category:asdf 0
DPS Used for 1HP(0.75kW) 3A Motor, Single to 3
DPS Used for 1HP(0.75kW) 3A Motor, Single to 3
DPS Used for 1HP(0.75kW) 3A Motor, Single to 3
DPS Used for 1HP(0.75kW) 3A Motor, Single to 3
DPS Used for 1HP(0.75kW) 3A Motor, Single to 3
DPS Used for 1HP(0.75kW) 3A Motor, Single to 3
DPS Used for 1HP(0.75kW) 3A Motor, Single to 3
DPS Used for 1HP(0.75kW) 3A Motor, Single to 3
DPS Used for 1HP(0.75kW) 3A Motor, Single to 3
DPS Used for 1HP(0.75kW) 3A Motor, Single to 3

DPS Used for 1HP(0.75kW) 3A Motor, Single to 3 Phase Converter, My-PS-2, 1 DPS Must Be Used for 1 Motor Only, Input/Output 200-240V, UL Listed

Product ID : 45495892


Galleon Product ID 45495892
UPC / ISBN 793072636306
Shipping Weight 0.66 lbs
I think this is wrong?
Model MY-PS-2
Manufacturer DPS
Shipping Dimension 6.22 x 4.21 x 2.32 inches
I think this is wrong?
-
9,038

*Price and Stocks may change without prior notice
*Packaging of actual item may differ from photo shown
  • Electrical items MAY be 110 volts.
  • 7 Day Return Policy
  • All products are genuine and original
  • Cash On Delivery/Cash Upon Pickup Available

Pay with

DPS Used for 1HP(0.75kW) 3A Motor, Single to 3 Features

  • DPS can run 3-phase motor with single-phase

  • Very easy to connect DPS and motor/Very easy to use

  • Small size & light weight

  • Even after the motor starts, 3-phase power continues to be supplied

  • Achieved UL listed(UL-US-2328605-1, UL-CA-2324527-1)

  • Digital Type Phase Converter/Excellent start-up torque

  • Low failure rate/Designed to be non-flammable

  • Keeps out dust, moisture, and heat due to the sealed type

  • Doesn’t make any high frequency/Lower power consumption

  • Efficiency is excellent versus others phase converters


About DPS Used For 1HP(0.75kW) 3A Motor, Single To 3

▷ Before ordering our DPS, you should check the ampere of your motor and purchase the suitable our DPS. And please give us the information about your motor purpose to recommend suitable DPS to you. Also, please note the below points carefully. 1. This item is worked at 1HP motor.(0.75KW, 3 amps) 2. The efficiency is around 90~95%. 3. The input/output voltage of our DPS is 200v~240v. 4. The voltage of the motor should be 200v~240v. If the voltage of your motor is 380v or 440v, you should change the wire of the motor to 200v~240v purpose to connect with the output of our DPS. 5. This item should be used as one DPS per one motor. Multiple motors are not allowed. 6. The thickness of the wires should be suitable for ampere. 7. Only a single-phase motor brake is allowed.(Three-phase the motor brake is not working at our DPS) 8. You could check three-phase on the output of DPS when your motor is running. If your motor is not running, you could not check three-phase from the output of DPS. 9. If your motor has a magnetic starter, or electronic switch, or brake, the operating wires of this device should be connected on “U” and “W” of the output of our phase converter. Thus, if your motor is not running well or the motor is reversing, you should turn off the power immediately and you have to switch the wires on output(U, V, W) of our phase converter. Actually, when you connect the wires from the output of the phase converter to your motor, you could succeed in the first time, or second time, or third time.