APC AP8841 RACK PDU
APC AP8841 RACK PDU

APC AP8841 RACK PDU 2G, Metered, ZEROU, 30A, 200/208V, (36) C13 & (6) C19 Output Connections Metered Rack PDU

Product ID : 2912203
4.7 out of 5 stars


Galleon Product ID 2912203
UPC / ISBN 731304277002
Shipping Weight 19.75 lbs
I think this is wrong?
Model AP8841
Manufacturer APC
Shipping Dimension 78.82 x 6.61 x 4.41 inches
I think this is wrong?
-
Save 27%
Before ₱ 74,634
54,264

*Price and Stocks may change without prior notice
*Packaging of actual item may differ from photo shown

Pay with

APC AP8841 RACK PDU Features

  • 200V-240V Input, Metered 1Ph 30A rackmount Power Distribution Unit

  • Input: NEMA L6-30P (5.0 kW)

  • Output Receptacles: Thirty-Six (36) C13 Outlets, and six (6) C19 Outlets

  • 0U Vertical Mounting PDU

  • Cord Length: 9.8 feet


About APC AP8841 RACK PDU

From the Manufacturer Superior Equipment and Data Protection Why buy APC by Schneider Electric? Over the years, APC by Schneider Electric has received hundreds of awards worldwide - more than any other power protection manufacturer. Such designations have recognized APC by Schneider Electric for both its reliable solutions and its overall business performance. RACK PDU 2G, METERED, ZEROU, 30A, 200/208V, (36) C13 & (6) C19 Metered rack PDUs provide real-time remote monitoring of connected loads. User-defined alarms warn of potential circuit overloads before critical IT failures occur. APC by Schneider Electric Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. New AP8000 series Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, Command Line Interface, or Telnet Interfaces which are complimented by Schneider Electric's StruxureWare solution. Metered Rack PDU Features & Benefits Availability Remote Management Capabilities Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements. Local Current Monitoring Display The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. Alarm Thresholds Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment). Alarm Thresholds Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability) Load indicator LED Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits. Flash Upgradeable Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only) Technical Specifications Output Nominal Output Voltage 208V Maximum Total Current Draw per Phase 24A Output Connections (36) IEC 320 C13 (6) IEC 320 C19 Overload Protection Yes Input Nominal Input Voltage 208V Input Frequency 50/60 Hz Regulatory Derated Input Current (North America) 24A Input Connections NEMA L6-30P Cord Length 2, 74 meters Number of Power Cords 1 Acceptable Input Voltage 200-240 VAC Maximum Input Current per phase 30A Physical Net Weight 6.84 kg Maximum Height 1791.00 mm Maxiumum Width 56.00 mm Maximum Depth 44.00 mm Shipping Weight 8.47 kg Shipping Height 2000.00 mm Shipping Width 162.00 mm Shipping Depth 107.00 mm Color Black Environmental Operating Environment -5 - 45 °C Operating Relative Humidity 5 - 95% Operating Elevation 0 - 3000 meters Storage Temperature -25 - 65 °C Storage Relative Humidity 5 - 95% Storage Elevatio