All Categories
Get it between 2025-07-04 to 2025-07-11. Additional 3 business days for provincial shipping.
【PARAMETER】ATO 1/2 HP 0.4KW single phase 220V input & output VFD variable frequency drive, for single phase AC motor
【VARIABLE FREQUENCY DRIVE】 Input voltage: 1 phase AC 220V, Input frequency: 47~63Hz, Output voltage: 1 phase AC 220V, Output frequency : 0~500Hz
【FLEXIBLE DESIGN】ATO 220V single phase output vfd, has VF control. Single phase vfd drive can be widely used for speed control accuracy, torque response speed, low-frequency output
【APPLICATION】ATO 220V/230V single phase to single phase VFD drive specialized designed for single phase induction motor, widely applied to control speed of the single phase motors, such as fans, pumps, mixer, extruder, slitter, winder, power tools, etc
【CUSTOMER FIRST】If you have no experience in driving a VFD, be sure to refer to the instructions before operating a VFD. If you are not sure about the size or have any issue about the product or service, please don't hesitate to email us. We will answer you within 12h
Specification: Basics Model:GK3000-1S0004 Capacity:1/2 hp (0.4 kW) Shipping weight:1.2 kg Dimension:124.8*78*148.4 mm Rated current:4 A Over load capacity:150% of rated current for 60s, 180% of rated current for 10s, 200% of rated current for 3s Control mode:V/f control Operation command mode:Keypad control, Terminal control, Serial communication control Frequency setting mode:Digital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combined & switched in various modes. Simple PLC & multi-step speed operation:It can realize a maximum of 16 segments speed running via the built-in PLC or control terminal. Built-in PID:Built-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.) Automatic voltage regulation:Keep output voltage constant automatically when input voltage fluctuating Control Function Common DC bus: Common DC bus for several VFDs, energy balanced automatically Torque control:Torque control without PG Torque limit "Rooter" characteristics, limit the torque automatically and prevent frequent over-current tripping during the running process Wobble frequency control Multiple triangular-wave frequency control, special for textile Timing/length/counting control:Timing/length/counting control function Over-voltage & over-current stall control Limit current & voltage automatically during the running process, prevent frequent over-current & over-voltage tripping