All Categories
Get it between 2025-08-26 to 2025-09-02. Additional 3 business days for provincial shipping.
Wide timing range: ICStation time relay delay is able to tolerate the widest timing adjusting range: 0-999S/ 0-999M/ 0-999H,it is available for various application.(Please Note: If the T1 time is second,the T2 time must be second. They can not achive T1 time is second and T2 time is minute/hour.)
Wide supply voltage range: Icstation timer relay supports AC85-265V. This device can support different work mode, If you are not clear the operation, please download the PDF user manual or Email us.
Cycle Timer relay supports sleep working mode, which will turn off automatically after 10s(need to set ). It is also very easy to set parameter via 4 momentary keys.
Parameter:Cycle Timer relay Support Voltage Input: AC85-265V, Maximum Power: <2000W, Maximum Current: 10A, Module Size: 71x39x25mm/2.80"x1.54"x0.98" (L*W*H).
Application:The Digital timer delay can be used for timing, delay, cycle timing, intermittent timing occasions and so on, such as the descending machine DIY, timing switch, timing alarm control board. Kindly Tips: We have uploaded the user manual on the Amazon page at technical specification or under the IMAGE, please download it and read it before you use it.
Instructions (more details please download the English User Manual in the Product Information):Time Setting: Short press "SET" to enter the time setting mode, and the T1 LED digit tube will flash, press the "UP" & "Down" to set the time "T1", then short press the "SET" again, the T2 LED digit tube will flash, press the "UP" & "Down" to set the time "T2", here are two ways to save the setting, one is wait 6s and the module will save the parameter automatically, the other way is to shore press "SET" again to save.Working Mode Setting: long press "SET" to enter the working mode setting and includes P0, P1, P2.1) PO--0 means the timing unit is 0.1s;2) PO--1 means the timing unit is second;3) PO--2 means the timing unit is minute;4) PO--3 means the timing unit is hour; 5) P1--0 means delay T1 time then the relay close (T1 timing);6) P1--1 means delay T1 time then the relay open (T1 timing);7) P1--2 means delay T1 time then the relay close (T1 timing), and delay T2 time then the relay open (T2 timing);8) P1--3 means delay T1 time then the relay open (T1 timing), and delay T2 time then the relay close (T2 timing);9) P1--4 means delay T1 time then the relay close(T1 timing), and delay T2 time then the relay open(T2 timing) and repeat this process 10) P1--4 means delay T1 time then the relay open (T1 timing), and delay T2 time then the relay close (T2 timing) and repeat this process;P2--0 to P2--5 is the LED display brightness adjustment.P2--OFF: low power consumption mode, the module will automatically turn off the LED display after 10s and press any kep to turn it on."OK" key function:1) after finishing all the parameter setting, press "OK" to save the parameter. During the working process, press the "OK" to pause the working mode and the relay will open, press again to work;2) Trigger again function: when the module finish the working mode, press "OK" can restart this working mode.