X
Uranium Ore
Uranium Ore
Uranium Ore
Uranium Ore

Uranium Ore

Product ID : 5544798
4.4 out of 5 stars


Galleon Product ID 5544798
UPC / ISBN 410000210390
Shipping Weight 0 lbs
I think this is wrong?
Model
Manufacturer Images SI
Shipping Dimension 5.98 x 5.98 x 4.02 inches
I think this is wrong?
-
4,530

*Price and Stocks may change without prior notice
*Packaging of actual item may differ from photo shown
  • Electrical items MAY be 110 volts.
  • 7 Day Return Policy
  • All products are genuine and original
  • Cash On Delivery/Cash Upon Pickup Available

Pay with

Uranium Ore Features

  • Radioactive Ore Sample (NORM) Naturally Occurring Radioactive Materials

  • License Exempt - low radioactive ore sample size and CPM activity will vary.

  • Useful for testing Geiger counters and performing nuclear experiments

  • Shipping compiles to Federal NRC and postal regulations

  • Radioactive minerals are for educational and scientific use only.


About Uranium Ore

Radioactive Ore Specimen. The ore sample is Naturally Occurring Radioactive Materials (NORM). Uranium Ore samples are useful as check sources for testing Geiger Counters. No analysis is performed on the ore sample. So the source of the ore's radioactivity may be any number of radioactive elements or decay products. Counts Per Minute (CPM) activity rate listed on the label is the activity level that includes all radiation types: alpha, beta and gamma. Since alpha radiation is the main form of radioactivity given off by the ore sample, if your Geiger counter can not detect alpha radiation it will show a much lower Counts Per Minute (CPM). When checking with an alpha sensitive Geiger counter it is important to set the Geiger counter to its CPM mode and to locate the hot spot on the ore sample. Each ore sample is checked and measured for its radioactivity using an NRC certified Digital Geiger counter that has passed ANSI-STD N323A calibration using a NIST traceable source from an independent government licensed lab conforming to NRC regulations 10-CFR-34, 10-CFR-35, making the Geiger counter suitable for regulatory inspections. License exempt. Radioactive ore sample size and CPM activity will vary. Shipped in labeled metal container as shown. Disposal: US Federal Regulations do not require any special requirements to dispose of NORM material, however local city and state regulations may differ from Federal Regulations. One needs to check with local regulators on how to dispose of NORM material. Shipping Information: We are always in compliance with Section 13 from part 40 of the NRC Nuclear Regulatory Commission rules and regulations and Postal Service regulations specified in 49 CFR 173.421 for activity limits of low level radioactive materials. The item is shipped in accordance with Postal Service activity limits specified in Publication 52.