X
FFU HEPA H14-Filter Laminar Flow Hood Updated
FFU HEPA H14-Filter Laminar Flow Hood Updated
FFU HEPA H14-Filter Laminar Flow Hood Updated
FFU HEPA H14-Filter Laminar Flow Hood Updated
FFU HEPA H14-Filter Laminar Flow Hood Updated
FFU HEPA H14-Filter Laminar Flow Hood Updated
FFU HEPA H14-Filter Laminar Flow Hood Updated
FFU HEPA H14-Filter Laminar Flow Hood Updated
FFU HEPA H14-Filter Laminar Flow Hood Updated

FFU HEPA H14-Filter Laminar Flow Hood Updated FanFilter Unit 100/ISO Class 5 Cleanroom/Laboratory/Cleanroom/Mycological Work/Mushroom with Safety Lock Laminar Air Flow Hood(22.6”x22.6”110V)

Product ID : 49876676


Galleon Product ID 49876676
UPC / ISBN 797085883115
Shipping Weight 36.25 lbs
I think this is wrong?
Model
Manufacturer
Shipping Dimension 25.24 x 25.24 x 14.49 inches
I think this is wrong?
-
40,102

*Price and Stocks may change without prior notice
*Packaging of actual item may differ from photo shown

Pay with

FFU HEPA H14-Filter Laminar Flow Hood Updated Features

  • FFU HEPA H14 filter laminar flow hood: FFU HEPA H14 filter laminar flow hood has CE and ISO certification. The HEPA H14 filtered laminar flow hood ensures that work surfaces are constantly filled with air in a laminar flow manner, and the updated fan filter unit captures 99.99% of particles larger and smaller than 0.3 microns in diameter, with filtration efficiency meeting 100/IS0 Level 5 cleanliness.

  • FFU HEPA H14 filter laminar flow hood product material: FFU HEPA H14 filter laminar flow hood is made of galvanized frame, aluminum fan blades, pure copper motor and thickened metal casing, using a safety lock to secure the fan filter Unit work is more durable, safe and efficient.

  • FFUHEPA H14 filter laminar flow hood parameters: 22.6”x22.6”x8.6”, the filtered air flow speed can be set to three speeds, the filtered air flow is 0.45m/s (±20%), the air volume is 600-700m3/H (depending on the working environment)

  • Ease of use:The fan filter laminar flow hood supports 110V American plug, which can be used for dust-free clean room, laboratory, tissue culture seedlings, laminating machine (mobile phone film), and repairing of mobile phone LCD display laboratory etc.

  • FFUHEPA H14 filter laminar flow hood is carefully inspected and packaged by us before shipment. You can use it with confidence!


About FFU HEPA H14-Filter Laminar Flow Hood Updated

FFU HEPA filter laminar flow hood updated fan filter unit, used in dust-free clean room, laboratory, tissue culture seedlings, laminating machine (mobile phone film), used for mobile phone LCD repair laboratory etc. Product parameters: Size: 22.6*22.6*8.6 inches Cabinet material: galvanized plate Wheel blade material: aluminum blade Filtration efficiency: 100/ISO level 5 Wind speed: 0.45m/s±20% Air volume: 600-700m3/h (depending on the working environment) Cleanliness: Class 100 (US Federal Standard 209E) Noise: Low speed 41-51. Medium speed 52-59 High speed 59-65 Vibration value: ≤0.45m/s2 Voltage: AC110V, 50HZ, single phase Power: 1200W Speed regulation mode: three gear speed regulation Wiring method: American standard three plug Maintenance 1. Do not open and close the filter repeatedly. 2. Do not operate the machine with wet hands, otherwise there is a danger of electric shock. 3. Do not block the intake valve with any other objects. The fan filter laminar flow hood needs to be kept away from heaters or other heat sources. 4. Wipe the laminar air supply unit frequently to keep it clean. 5. The fan filter laminar flow hood should be replaced regularly (per cycle every 8-12 months): After replacing the high-efficiency filter, the laminar air supply should be re-tested The technical parameters of the unit can only continue to work after meeting the requirements. Detection It is recommended to use a particle counter regularly to detect dust particles in the working area of the fan filter laminar flow hood in accordance with the US federal standard The number (cleanliness) and whether the filter is leaking.