X
Category:asdf 0
AEMC L102 Simple Logger II, Two-Channel TRMS
AEMC L102 Simple Logger II, Two-Channel TRMS

AEMC L102 Simple Logger II, Two-Channel TRMS Current, 1V AC Input Range

Product ID : 6949566


Galleon Product ID 6949566
UPC / ISBN 685338140347
Shipping Weight 1.35 lbs
I think this is wrong?
Model L102
Manufacturer AEMC
Shipping Dimension 10.51 x 6.89 x 2.8 inches
I think this is wrong?
-
Product is Out of Stock as of Oct, 09 2025
Want to monitor availability?
of brand new stock?
or
Need this item ASAP?
Check if this is available on Amazon
or available in other sites
Send us the link so we can buy for you

Pay with

AEMC L102 Simple Logger II, Two-Channel TRMS Features

  • Two independent channels

  • Compatible standard current probes with voltage output and BNC connection

  • 64 Samples per cycle

  • Programmable storage rates from 8 every second to 1 every day

  • 3 User selectable storage modes


About AEMC L102 Simple Logger II, Two-Channel TRMS

Simple logger II compatible with standard AC current probes with voltage output and BNC connection. 3 user selectable storage modes. Stores up to 240,000 measurements in non-volatile memory. Powered by standard Alkaline batteries. Lightweight, compact, fits anywhere. 5 LED indicators quickly and clearly display logger status. Includes FREE DataView software for data storage, real-time waveform display, analysis and report generation. Isolated USB communication. USB cable included. 50V Cat. III. Applications: Split phase load monitoring, Neutral and ground current monitoring, Intermittent problem detection, Harmonic current monitoring using DataView software, Machine load monitoring, Start-Stop time stamping. Current probe output voltage range 0 to 1V (probe dependent). Resolution: 0.1mV. Accuracy (50/60Hz): 0 to 10mV: unspecified, 10 to 50mV: +/- (0.5percent of Reading + 1mV), 50 to 1000mV: +/-(0.5percent of Reading + 0.5mV). Sample rate: 64 samples/cycle. Storage rate: Programmable from 125mS to 1 day. Storage modes: Start/Stop, FIFO and Extended Recording Mode (XRM"). Recording length: 15 minutes to 8 weeks, programmable using DataView. Memory: 240000 measurements (512KB) The recorded data is stored in non- volatile memory and retained even if the battery is low or removed. Communication: USB 2.0 optically isolated. Power source: 2 x 1.5V AA-cell Alkaline batteries. Battery life: 100 hrs to > 45 days (dependent on storage rate/recording length). Max conductor size. Current probe dependent. Case: UL94-V0. Vibration: IEC 68-2-6 (1.5mm, 10 to 55Hz). Operating Temperature: 14 to 122 degree F (-10 degree to 50 degree C). Storage temperature: -4 to 140 degree F (-20 degree to 60 degree C). Measures 2-3/4" width by 5-3/8" height by 1-17/64" depth.