X
YYB-5 12V 24V Motor Forward, 0.1 Seconds to 999
YYB-5 12V 24V Motor Forward, 0.1 Seconds to 999
YYB-5 12V 24V Motor Forward, 0.1 Seconds to 999
YYB-5 12V 24V Motor Forward, 0.1 Seconds to 999
YYB-5 12V 24V Motor Forward, 0.1 Seconds to 999
YYB-5 12V 24V Motor Forward, 0.1 Seconds to 999
YYB-5 12V 24V Motor Forward, 0.1 Seconds to 999
YYB-5 12V 24V Motor Forward, 0.1 Seconds to 999
YYB-5 12V 24V Motor Forward, 0.1 Seconds to 999

YYB-5 12V 24V Motor Forward, 0.1 Seconds to 999 Minutes Time Adjustable Automatic Reverse Forward Relay Timer Relay/Reverse Control Board Two Relay Delay Timing Cycle Module

Product ID : 49525339


Galleon Product ID 49525339
Shipping Weight 0.22 lbs
I think this is wrong?
Model Eujgoovzdtby1x2a4
Manufacturer Eujgoov
Shipping Dimension 3.94 x 3.54 x 1.18 inches
I think this is wrong?
-
No price yet.
Price not yet available.

Pay with

YYB-5 12V 24V Motor Forward, 0.1 Seconds to 999 Features

  • HIGH QUALITY: 100% brand new and high quality

  • COMMONLY USED FUNCTIONS: 6 kinds of commonly used functions to meet the needs of more applications;

  • OUTPUT POWER: it can control within 30A DC or AC load

  • APPLICATIONS: It can control 2-way solenoid valve, pumps, motors, lights and other running freely

  • TIME RANGE: 0.1 seconds to 999 minutes any time adjustable


About YYB-5 12V 24V Motor Forward, 0.1 Seconds To 999

Features: 100% brand new and high quality 6 kinds of commonly used functions to meet the needs of more applications; It can control 2-way solenoid valve, pumps, motors, lights and other running freely Output power: it can control within 30A DC or AC load Time range: 0.1 seconds to 999 minutes any time adjustable Specification: Model:YYB-5 Input voltage: DC/ AC7V~27V Time range: 0.1 seconds to 999 minutes Weight: Approx.103g/3.6oz Wiring port Description: 1. AC/DC : Input 7V~27V 3. IN1: Signal input 1 (negative trigger) 4. IN2: Signal input terminal 2 (negative trigger) 2. IN3: Signal input 3 (negative trigger) 5. NO: relay normally open interface, relay pull before the suspension, after the connection with the COM shorted 6. COM: relay common interface 7. NC: relay normally closed interface, the relay before the connection with the COM shorted, pull after the suspension Function list: P - 1: to signal 1, relay 1 pulls to A time automatically stops; to signal 2, relay 2 pulls to B time automatically stops; signal 3 is emergency stop reset signal P - 2: signal 1, relay 1 is pulled to A time automatically stop; relay 2 from the signal to start delay B time after the suction to C time automatically stop (this function time unit needs to be consistent) P - 3: After power on, relay 1 pulls up to A time release, waiting for C time, relay 2 pulls to B time release, waits for C time; relay 1,2 turns endless operation endless cycle (If the control motor is reversible can be understood as: the motor is running a period of time; stop for some time; automatically reverse for some time; stop for some time; then automatically forward; P - 4: to signal 1, relay 1 pull; to signal 2 (limit), relay 1 stops and starts counting to A time relay 2