X
MXBAOHENG QCT Thick Paint Putty Consistency
MXBAOHENG QCT Thick Paint Putty Consistency
MXBAOHENG QCT Thick Paint Putty Consistency
MXBAOHENG QCT Thick Paint Putty Consistency
MXBAOHENG QCT Thick Paint Putty Consistency
MXBAOHENG QCT Thick Paint Putty Consistency
MXBAOHENG QCT Thick Paint Putty Consistency
MXBAOHENG QCT Thick Paint Putty Consistency

MXBAOHENG QCT Thick Paint Putty Consistency Determination Apparatus Putty Consistency Tester Consistometer

Product ID : 36666847


Galleon Product ID 36666847
Shipping Weight 11.02 lbs
I think this is wrong?
Model
Manufacturer MXBAOHENG
Shipping Dimension 0 x 0 x 0 inches
I think this is wrong?
-
No price yet.
Price not yet available.

Pay with

MXBAOHENG QCT Thick Paint Putty Consistency Features

  • The implementation of the standard: GB/T1749-89


About MXBAOHENG QCT Thick Paint Putty Consistency

Description: QCT thick paint and putty consistency tester is designed and manufactured according to GB1749. Used to determine the consistency of thick paint or putty. After a period of time under fixed pressure, the thickness of the sample was represented by the diameter of flow diffusion. Technical Parameters: Pump inner diameter:Φ29.7mm Pump depth: 29mm Pump volume: 20.70ml Glass plate: 20*20*0.6cm Weight: 3.5kg Farmar weight:2000g±10g Usage: 1. Place the bottom glass plate on the flat test table, put the pump in the center of the glass (with the marking line one side down), fill the sample with the paint knife and scrape the sample. (no space left in the sample) 2. Extrude the sample in the pump with the pump plug. (note that when pressing the pump plug, lift the pump upward.) cut off the sample on the pump plug with a paint knife and place it in the center of the glass plate. 3. Align the circle center of the glass plate with the center of the sample, place the weight gently on the sample, and then put the weight on the center of the glass plate, open the stopwatch at the same time, remove the weight after one minute, observe the scale of the sample flow spread on the circle on the glass plate, and record the diameter centimeters, that is, the test result. (if it is an ellipse, take the average of its major and minor axes) Attention: 1. The test shall be carried out under the condition of constant temperature and humidity or under the conditions agreed upon by the parties concerned. 2. After the test, clean the glass plate, pump and pump plug with solvent, put them in the box and put them in the dry place for next use.