X
Leviton DOS02-1LW Decora Motion Sensor In-Wall
Leviton DOS02-1LW Decora Motion Sensor In-Wall
Leviton DOS02-1LW Decora Motion Sensor In-Wall
Leviton DOS02-1LW Decora Motion Sensor In-Wall
Leviton DOS02-1LW Decora Motion Sensor In-Wall

Leviton DOS02-1LW Decora Motion Sensor In-Wall Switch, Auto-On, 2.5A, Single Pole, White

Product ID : 1406433
4.4 out of 5 stars


Galleon Product ID 1406433
UPC / ISBN 078477617984
Shipping Weight 0.26 lbs
I think this is wrong?
Model DOS02-1LW
Manufacturer Leviton
Shipping Dimension 6.14 x 3.94 x 2.44 inches
I think this is wrong?
-
Before ₱ 2,463
2,441

*Price and Stocks may change without prior notice
*Packaging of actual item may differ from photo shown
  • Electrical items MAY be 110 volts.
  • 7 Day Return Policy
  • All products are genuine and original
  • Cash On Delivery/Cash Upon Pickup Available

Pay with

Leviton DOS02-1LW Decora Motion Sensor In-Wall Features

  • Automatic ON/Automatic OFF provides 180 Degree field of view and 900 square feet of coverage

  • 300W Incandescent / Halogen, 150W LED / CFL, 200VA Fluorescent, 1/6HP Motor loads

  • Fits in standard wallbox and replaces single pole wall switch, no Neutral wire required for installation but ground wire is required


About Leviton DOS02-1LW Decora Motion Sensor In-Wall

Product Description Leviton’s IPV02/IPS02 universal vacancy and occupancy sensors combine state-of-the-art technology with new aesthetics to provide optimal management of lighting and motor loads and a choice of either manual-on (vacancy sensor) or automatic-on (occupancy sensor) switching. These energy-saving sensors are engineered to control current LED, CFL, electronic and magnetic low voltage and incandescent loads and ensure that lights/motors will turn on manually (vacancy) or automatically (occupancy) and turn off automatically when motion is no longer detected within the covered range. Designed to fit in a standard wallbox, both devices offer 180° Field of View and 900 sq. ft. of coverage. All models have screw terminals for easy installation and do not require a neutral wire for connection. The devices feature a time delay setting which allows users the option to delay the lights/motor load from switching off for 30 seconds, 5 minutes, 15 minutes or 30 minutes. For example, closet lighting would ideally be set to turn off in 30 seconds while a bathroom fan may be set to turn off 15 minutes after the space is vacated. The IPV02/IPS02 is single pole, relay-based and designed to replace a single pole switch for loads such as exhaust fans. It is compatible with LED, CFL, Incandescent, Fluorescent and motor loads. Amazon.com Lower electrical costs and add convenience to everyday living by replacing standard switches with occupancy sensors. Leviton's IPS02 Occupancy Sensor Switch automatically turns the lights ON when you enter a room and OFF when you leave, convenient in rooms where you frequently enter and exit with your hands full. Ideal for use in laundry rooms, basements, storage areas, pantries and garages. Leviton occupancy sensors are a simple, cost effective way to automate a space in your home. Features and Benefits A simple and effective way to save energy and the associated electric costs. Actual savings from sensors vary greatly depending on usage patterns and occupant habits, but used diligently the energy savings and reduced frequency of bulb replacement over time can provide significant cost savings. Time delay settings of 30 seconds, 5 minutes, 15 minutes or 30 minutes for automatic OFF. For example, closet lighting would ideally be set to turn off in 5 minutes while a bathroom fan may be set to turn off 15 minutes after the space is vacated. Contains a built-in override function, so the device can be activated to operate as a vacancy sensor meaning lights must be manually switched ON but will automatically turn OFF when the room is vacated. Does not require a neutral wire for installation making them perfect for retrofit applications where a neutral wire may not be present. A ground wire is required for operation. Perfect for areas where you may have your hands full such as laundry rooms, kitchens, garages, basements, pantries and storage areas rooms. view larger Installation and Placement Considerations Leviton Universal Sensors use passive infrared (PIR) technology to detect movement so there are a number of factors that must be considered when installing them: They require a clear view of the room or space for accurate detection—any furniture or obstructions that block the sensor’s view will prevent occupant’s movement from being detected For optimal performance, locate with a clear line-of-view of the area to be covered; perpendicular to the likely movement They are most effective in small, enclosed areas with high levels of occupant motion Size and shape of area needing coverage must be in line with the range of the occupancy sensor The more activity there is in a space, the more sensors will contribute to energy savings and convenience Avoid installing in locations where nearby airflow may falsely register as motion; be mindful of the location of heating units, air conditioners, dryers and other large appliances that generate rapid changes in temperature or movement Increase your energy savings an