HFBTE Lab Turbidimeter Multiparameter Benchtop Turbidity Meter with Range 0 to 2000 NTU/FNU 0 to 500 EBC 0 to 9999 ASBC 4 Selectable Turbidity Units 200 Data Storage USB Communication Interface

Product ID : 48967820


Galleon Product ID 48967820
UPC / ISBN 794590795766
Shipping Weight 7.72 lbs
I think this is wrong?
Model
Manufacturer HFBTE
Shipping Dimension 13.78 x 9.84 x 7.87 inches
I think this is wrong?
-
No price yet.
Price not yet available.

Pay with

HFBTE Lab Turbidimeter Multiparameter Benchtop Features

  • Selectable 4 turbidity units, including the NTU, FNU, EBC and ASBC.

  • 2 to 7 points push-button calibration using the formazin standards.

  • Turbidity Range:0~2000 NTU/FNU, 0~500 EBC, 0~9999 ASBC

  • Applications: Industrial wastewater plants Municipal water and other industrial applications

  • Multiparameter benchtop turbidity meter with the Total Suspended Solids measurement mode, 2 to 7 points calibration, selectable 4 turbidity units. The meter is suitable for laboratory use.


About HFBTE Lab Turbidimeter Multiparameter Benchtop

HFBTE Lab Turbidimeter Multiparameter Benchtop Turbidity Meter With Range 0 To 2000 NTU/FNU 0 To 500 EBC 0 To 9999 ASBC 4 Selectable Turbidity Units 200 Data Storage USB Communication Interface Introduction: ◆Multiparameter benchtop turbidity meter with the Total Suspended Solids measurement mode, 2 to 7 points calibration, selectable 4 turbidity units. The meter is suitable for laboratory use. Features: ◆Multiparameter benchtop turbidity meter is equipped with a 4.5 inches TFT display ◆2 to 7 points calibration using the Formazin Standards ◆Selectable 4 turbidity units, including the NTU, FNU, EBC and ASBC ◆TSS conversion factor ensures the accurate measurement of the total suspended solids ◆Auto-Read function senses and locks a stable reading ◆Setup menu allows setting the date and time, measurement mode, resolution, auto-power off,etc ◆Password protection prevents the unauthorized calibration and settings ◆Expanded memory stores or recalls up to 200 data sets ◆Reset function automatically resumes all settings back to the factory defaults ◆USB communication interface is easy to transfer data to PC Specifications ◆Measurement Method:ISO 7027 nephelometric method (90°) ◆Turbidity Range:0~2000 NTU/FNU, 0~500 EBC, 0~9999 ASBC ◆Total Suspended Solids Range:Deponds on TSS factor setting ◆Resolution:0.01 (0~100 NTU), 0.1 (100~999 NTU), 1 (999~2000 NTU) ◆Accuracy:±2% (0~500 NTU), ±3% (501~2000 NTU) ◆Calibration Points:2~7 points (0.02, 10.00, 200, 500, 1000, 1500, 2000 NTU) ◆Light Source:Infrared-emitting diode (850nm wavelength) ◆Detector:Silicon Photodiode ◆Stray Light: